{"id":680,"date":"2026-01-28T21:22:12","date_gmt":"2026-01-29T00:22:12","guid":{"rendered":"https:\/\/demo.peregrine-themes.com\/bloghash\/default\/?p=44"},"modified":"2026-01-28T21:26:25","modified_gmt":"2026-01-29T00:26:25","slug":"ais-transformative-path-in-art-evolution","status":"publish","type":"post","link":"https:\/\/machservicos.com.br\/?p=680","title":{"rendered":"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">\ud83d\udcd0 Norma de conex\u00e3o <strong>TIA\/EIA-568A<\/strong> e <strong>TIA\/EIA-568B<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">As normas <strong>TIA\/EIA-568A<\/strong> e <strong>TIA\/EIA-568B<\/strong> definem o <strong>padr\u00e3o de crimpagem<\/strong> (ordem das cores dos fios) em cabos de rede <strong>par tran\u00e7ado<\/strong> (Cat5e, Cat6, Cat6A etc.) com <strong>conector RJ45<\/strong>.<br>Elas garantem <strong>padroniza\u00e7\u00e3o, compatibilidade e desempenho<\/strong> em redes Ethernet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esses padr\u00f5es s\u00e3o usados em:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Redes estruturadas<\/li>\n\n\n\n<li>Automa\u00e7\u00e3o residencial e predial<\/li>\n\n\n\n<li>Telecomunica\u00e7\u00f5es<\/li>\n\n\n\n<li>Sistemas IP (c\u00e2meras, controle de acesso, VoIP, automa\u00e7\u00e3o, etc.)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udd27 Regras gerais da norma TIA-568<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Independente de ser <strong>A ou B<\/strong>, as regras s\u00e3o:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O cabo possui <strong>4 pares tran\u00e7ados (8 fios)<\/strong><\/li>\n\n\n\n<li>Cada par tem uma cor s\u00f3lida + uma branca com listra<\/li>\n\n\n\n<li>O <strong>tran\u00e7amento deve ser mantido o mais pr\u00f3ximo poss\u00edvel do conector<\/strong> (m\u00e1x. ~13 mm destran\u00e7ado)<\/li>\n\n\n\n<li>Ambos os lados do cabo devem seguir <strong>o mesmo padr\u00e3o<\/strong> (A-A ou B-B) para cabo <strong>direto<\/strong><\/li>\n\n\n\n<li>A pinagem \u00e9 contada <strong>com o clip do RJ45 para baixo<\/strong>, da esquerda (pino 1) para a direita (pino 8)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udfe2 Padr\u00e3o <strong>TIA\/EIA-568A<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Mais utilizado em <strong>instala\u00e7\u00f5es governamentais<\/strong>, projetos antigos e em alguns pa\u00edses fora do eixo comercial EUA.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Sequ\u00eancia de cores (pino 1 ao 8):<\/h5>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Branco \/ Verde<\/li>\n\n\n\n<li>Verde<\/li>\n\n\n\n<li>Branco \/ Laranja<\/li>\n\n\n\n<li>Azul<\/li>\n\n\n\n<li>Branco \/ Azul<\/li>\n\n\n\n<li>Laranja<\/li>\n\n\n\n<li>Branco \/ Marrom<\/li>\n\n\n\n<li>Marrom<\/li>\n<\/ol>\n\n\n\n<figure class=\"blockart-image blockart-image-457c8549\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-833 hover-effect-static filter-none mask mask-none\" src=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-5.jpg\" alt=\"\" height=\"500\" width=\"500\" srcset=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-5.jpg 500w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-5-300x300.jpg 300w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-5-150x150.jpg 150w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-5-45x45.jpg 45w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udd35 Padr\u00e3o <strong>TIA\/EIA-568B<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c9 o <strong>mais utilizado no Brasil e no mundo<\/strong>, principalmente em redes comerciais, data centers e automa\u00e7\u00e3o.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Sequ\u00eancia de cores (pino 1 ao 8):<\/h5>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Branco \/ Laranja<\/li>\n\n\n\n<li>Laranja<\/li>\n\n\n\n<li>Branco \/ Verde<\/li>\n\n\n\n<li>Azul<\/li>\n\n\n\n<li>Branco \/ Azul<\/li>\n\n\n\n<li>Verde<\/li>\n\n\n\n<li>Branco \/ Marrom<\/li>\n\n\n\n<li>Marrom<\/li>\n<\/ol>\n\n\n\n<figure class=\"blockart-image blockart-image-8c7e88ad\"><img decoding=\"async\" class=\"wp-image-834 hover-effect-static filter-none mask mask-none\" src=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-3.jpg\" alt=\"\" height=\"500\" width=\"500\" srcset=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-3.jpg 500w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-3-300x300.jpg 300w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-3-150x150.jpg 150w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/art002-3-45x45.jpg 45w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udd04 Cabo direto x Cabo crossover<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83d\udd39 Cabo direto (padr\u00e3o mais comum)<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>568A em ambos os lados<\/strong> ou<\/li>\n\n\n\n<li><strong>568B em ambos os lados<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Usado para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PC \u2194 Switch<\/li>\n\n\n\n<li>C\u00e2mera IP \u2194 Switch<\/li>\n\n\n\n<li>Automa\u00e7\u00e3o \u2194 Rede<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83d\udd39 Cabo crossover (menos usado hoje)<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Um lado <strong>568A<\/strong><\/li>\n\n\n\n<li>Outro lado <strong>568B<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Usado antigamente para:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PC \u2194 PC<\/li>\n\n\n\n<li>Switch \u2194 Switch (sem auto-MDI\/MDIX)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udc49 Hoje quase todos os equipamentos modernos fazem <strong>auto-negocia\u00e7\u00e3o<\/strong>, ent\u00e3o crossover virou exce\u00e7\u00e3o.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83e\udd14 Por que essas normas foram criadas?<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Antes da padroniza\u00e7\u00e3o, cada instalador montava cabos \u201cdo seu jeito\u201d, causando:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Incompatibilidade entre equipamentos<\/li>\n\n\n\n<li>Perda de desempenho<\/li>\n\n\n\n<li>Interfer\u00eancia eletromagn\u00e9tica (crosstalk)<\/li>\n\n\n\n<li>Dificuldade de manuten\u00e7\u00e3o<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">As normas <strong>TIA\/EIA-568<\/strong> foram criadas para:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2705 Padronizar instala\u00e7\u00f5es<br>\u2705 Garantir desempenho (100 Mbps, 1 Gbps, 10 Gbps\u2026)<br>\u2705 Facilitar manuten\u00e7\u00e3o e expans\u00e3o<br>\u2705 Evitar erros de crimpagem<br>\u2705 Manter a integridade dos pares tran\u00e7ados<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udccc Resumo r\u00e1pido<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>568A e 568B fazem a mesma coisa<\/strong> \u2192 s\u00f3 muda a posi\u00e7\u00e3o dos pares verde e laranja<\/li>\n\n\n\n<li><strong>No Brasil, use 568B<\/strong> (padr\u00e3o mais aceito)<\/li>\n\n\n\n<li>O mais importante \u00e9 <strong>consist\u00eancia<\/strong>: mesmo padr\u00e3o nos dois lados<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udcca Infogr\u00e1fico \u2013 Padr\u00f5es TIA\/EIA-568, Transmiss\u00e3o de Dados e PoE<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83d\udd0c Sequ\u00eancia de cores \u2013 568A x 568B (RJ45)<\/h5>\n\n\n\n<h6 class=\"wp-block-heading\">\ud83d\udfe2 Padr\u00e3o TIA\/EIA-568A<\/h6>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"blockart-image blockart-image-f7b2ff45\"><img decoding=\"async\" class=\"wp-image-835 hover-effect-static filter-none mask mask-none\" src=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/568a-vs-568b-chart_1024x1024.webp\" alt=\"\" height=\"499\" width=\"1024\" srcset=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/568a-vs-568b-chart_1024x1024.webp 1024w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/568a-vs-568b-chart_1024x1024-300x146.webp 300w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/568a-vs-568b-chart_1024x1024-768x374.webp 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ordem dos pinos (1 \u2192 8):<\/strong><br>Branco\/Verde \u00b7 Verde \u00b7 Branco\/Laranja \u00b7 Azul \u00b7 Branco\/Azul \u00b7 Laranja \u00b7 Branco\/Marrom \u00b7 Marrom<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udd35 Padr\u00e3o TIA\/EIA-568B<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ordem dos pinos (1 \u2192 8):<\/strong><br>Branco\/Laranja \u00b7 Laranja \u00b7 Branco\/Verde \u00b7 Azul \u00b7 Branco\/Azul \u00b7 Verde \u00b7 Branco\/Marrom \u00b7 Marrom<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udccc <strong>Observa\u00e7\u00e3o importante para o infogr\u00e1fico:<\/strong><br>\ud83d\udc49 A \u00fanica diferen\u00e7a entre 568A e 568B \u00e9 a <strong>troca dos pares verde e laranja<\/strong>.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udd01 Quais pares transmitem e recebem dados?<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83d\udce1 Ethernet 10\/100 Mbps (Fast Ethernet)<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Fun\u00e7\u00e3o<\/th><th>Pinos<\/th><th>Par<\/th><th>Cores (568B)<\/th><\/tr><\/thead><tbody><tr><td>Transmiss\u00e3o (TX)<\/td><td>1 e 2<\/td><td>Par 2<\/td><td>Branco\/Laranja + Laranja<\/td><\/tr><tr><td>Recep\u00e7\u00e3o (RX)<\/td><td>3 e 6<\/td><td>Par 3<\/td><td>Branco\/Verde + Verde<\/td><\/tr><tr><td>N\u00e3o usados<\/td><td>4,5,7,8<\/td><td>Pares 1 e 4<\/td><td>Azul e Marrom<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83e\udde0 <strong>Resumo t\u00e9cnico:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Apenas <strong>2 pares transmitem dados<\/strong><\/li>\n\n\n\n<li>Os pares <strong>azul e marrom ficam livres<\/strong> (e \u00e9 a\u00ed que o PoE entra em cena \ud83d\udc47)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\ude80 Ethernet 1000 Mbps (Gigabit)<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Pares usados<\/th><th>Pinos<\/th><\/tr><\/thead><tbody><tr><td>Todos os 4 pares<\/td><td>1 a 8<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udccc No Gigabit:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Todos os pares transmitem e recebem ao mesmo tempo<\/strong><\/li>\n\n\n\n<li>Comunica\u00e7\u00e3o <strong>full-duplex<\/strong><\/li>\n\n\n\n<li>Por isso a qualidade da crimpagem e do cabo \u00e9 cr\u00edtica<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\u26a1 PoE (Power over Ethernet) na pr\u00e1tica<\/h4>\n\n\n\n<figure class=\"blockart-image blockart-image-06d22e14\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-829 hover-effect-static filter-none mask mask-none\" src=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/Power-over-Ethernet-Cabling.png\" alt=\"\" height=\"662\" width=\"1089\" srcset=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/Power-over-Ethernet-Cabling.png 1089w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/Power-over-Ethernet-Cabling-300x182.png 300w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/Power-over-Ethernet-Cabling-1024x622.png 1024w, https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/Power-over-Ethernet-Cabling-768x467.png 768w\" sizes=\"(max-width: 1089px) 100vw, 1089px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83d\udd0c Como a energia trafega no cabo?<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83d\udd39 PoE Modo A (mais comum em switches)<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Energia passa nos <strong>mesmos pares de dados<\/strong><\/li>\n\n\n\n<li>Pinos: <strong>1\u20132 e 3\u20136<\/strong><\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83d\udd39 PoE Modo B (mais antigo)<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Energia passa nos <strong>pares n\u00e3o usados<\/strong><\/li>\n\n\n\n<li>Pinos: <strong>4\u20135 e 7\u20138<\/strong><\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83d\udd39 PoE moderno (802.3af \/ at \/ bt)<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pode usar <strong>todos os pares<\/strong><\/li>\n\n\n\n<li>Distribui\u00e7\u00e3o inteligente de energia<\/li>\n\n\n\n<li>At\u00e9 <strong>90W no PoE++ (802.3bt)<\/strong><\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">\ud83c\udfe0 Rela\u00e7\u00e3o direta com Automa\u00e7\u00e3o e C\u00e2meras IP<\/h4>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83d\udcf7 C\u00e2meras IP<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Usam <strong>dados + energia no mesmo cabo<\/strong><\/li>\n\n\n\n<li>Reduz:\n<ul class=\"wp-block-list\">\n<li>Fonte externa<\/li>\n\n\n\n<li>Ponto de tomada<\/li>\n\n\n\n<li>Falhas el\u00e9tricas<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Padr\u00e3o <strong>568B + PoE<\/strong> \u00e9 o mais usado no Brasil<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\">\ud83e\udde0 Automa\u00e7\u00e3o residencial e predial<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">Aplica\u00e7\u00f5es comuns:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Controladores IP<\/li>\n\n\n\n<li>M\u00f3dulos de I\/O<\/li>\n\n\n\n<li>Interfaces touch<\/li>\n\n\n\n<li>Gateways<\/li>\n\n\n\n<li>Sensores inteligentes<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\ud83d\udca1 <strong>Boas pr\u00e1ticas:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Sempre manter <strong>o mesmo padr\u00e3o em toda a obra<\/strong><\/li>\n\n\n\n<li>Preferir <strong>568B<\/strong><\/li>\n\n\n\n<li>Usar <strong>cabos 100% cobre<\/strong> para PoE<\/li>\n\n\n\n<li>Evitar destran\u00e7ar pares al\u00e9m do necess\u00e1rio<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\">\u2705 Conclus\u00e3o (ideal para fechar o infogr\u00e1fico)<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\">\u2714 568A e 568B s\u00e3o padr\u00f5es de <strong>organiza\u00e7\u00e3o dos pares<\/strong><br>\u2714 568B \u00e9 o mais adotado comercialmente<br>\u2714 Em 10\/100 Mbps s\u00f3 2 pares transmitem dados<br>\u2714 Em Gigabit e PoE moderno, <strong>todos os pares importam<\/strong><br>\u2714 Crimpagem correta = desempenho + confiabilidade<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Entenda a norma t\u00e9cnica que define regras de montagem dos conectores para cabos de rede e suas especifica\u00e7\u00f5es.<\/p>\n","protected":false},"author":1,"featured_media":830,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"audio","meta":{"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[31,32,36],"tags":[104,101,94,93,98,92,102,48,49,95],"class_list":["post-680","post","type-post","status-publish","format-audio","has-post-thumbnail","hentry","category-automacao","category-redes","category-technology","tag-cat6","tag-conecto","tag-eia","tag-ethernet","tag-norma","tag-redes","tag-rj45","tag-tech","tag-technology","tag-tia","post_format-post-format-audio"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE - MACH TECNOLOGIA<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/machservicos.com.br\/?p=680\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE - MACH TECNOLOGIA\" \/>\n<meta property=\"og:description\" content=\"Entenda a norma t\u00e9cnica que define regras de montagem dos conectores para cabos de rede e suas especifica\u00e7\u00f5es.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/machservicos.com.br\/?p=680\" \/>\n<meta property=\"og:site_name\" content=\"MACH TECNOLOGIA\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-29T00:22:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-29T00:26:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia-1024x683.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tony Machado\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tony Machado\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/machservicos.com.br\/?p=680#article\",\"isPartOf\":{\"@id\":\"https:\/\/machservicos.com.br\/?p=680\"},\"author\":{\"name\":\"Tony Machado\",\"@id\":\"https:\/\/machservicos.com.br\/#\/schema\/person\/6d4bcd2780673f815dfdd78bd1ad6a16\"},\"headline\":\"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE\",\"datePublished\":\"2026-01-29T00:22:12+00:00\",\"dateModified\":\"2026-01-29T00:26:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/machservicos.com.br\/?p=680\"},\"wordCount\":811,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/machservicos.com.br\/#organization\"},\"image\":{\"@id\":\"https:\/\/machservicos.com.br\/?p=680#primaryimage\"},\"thumbnailUrl\":\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png\",\"keywords\":[\"cat6\",\"conecto\",\"eia\",\"ethernet\",\"norma\",\"redes\",\"RJ45\",\"Tech\",\"Technology\",\"TIA\"],\"articleSection\":[\"Automa\u00e7\u00e3o\",\"Redes\",\"Tecnologia\"],\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/machservicos.com.br\/?p=680#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/machservicos.com.br\/?p=680\",\"url\":\"https:\/\/machservicos.com.br\/?p=680\",\"name\":\"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE - MACH TECNOLOGIA\",\"isPartOf\":{\"@id\":\"https:\/\/machservicos.com.br\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/machservicos.com.br\/?p=680#primaryimage\"},\"image\":{\"@id\":\"https:\/\/machservicos.com.br\/?p=680#primaryimage\"},\"thumbnailUrl\":\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png\",\"datePublished\":\"2026-01-29T00:22:12+00:00\",\"dateModified\":\"2026-01-29T00:26:25+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/machservicos.com.br\/?p=680#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/machservicos.com.br\/?p=680\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/machservicos.com.br\/?p=680#primaryimage\",\"url\":\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png\",\"contentUrl\":\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png\",\"width\":1536,\"height\":1024},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/machservicos.com.br\/?p=680#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/machservicos.com.br\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/machservicos.com.br\/#website\",\"url\":\"https:\/\/machservicos.com.br\/\",\"name\":\"MACH TECNOLOGIA\",\"description\":\"Automa\u00e7\u00e3o residencial e seguran\u00e7a eletr\u00f4nica\",\"publisher\":{\"@id\":\"https:\/\/machservicos.com.br\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/machservicos.com.br\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/machservicos.com.br\/#organization\",\"name\":\"MACH TECNOLOGIA\",\"url\":\"https:\/\/machservicos.com.br\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/machservicos.com.br\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2026\/01\/cropped-M-A-C-H-1.png\",\"contentUrl\":\"https:\/\/machservicos.com.br\/wp-content\/uploads\/2026\/01\/cropped-M-A-C-H-1.png\",\"width\":380,\"height\":76,\"caption\":\"MACH TECNOLOGIA\"},\"image\":{\"@id\":\"https:\/\/machservicos.com.br\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/machservicos.com.br\/#\/schema\/person\/6d4bcd2780673f815dfdd78bd1ad6a16\",\"name\":\"Tony Machado\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/machservicos.com.br\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/47a6fc2f54315f40bb8c95e5a60db9c729e16a1061eb46d64604c7247cef394b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/47a6fc2f54315f40bb8c95e5a60db9c729e16a1061eb46d64604c7247cef394b?s=96&d=mm&r=g\",\"caption\":\"Tony Machado\"},\"description\":\"Sou profissional de tecnologia com experi\u00eancia em seguran\u00e7a eletr\u00f4nica, automa\u00e7\u00e3o residencial e redes, focado em solu\u00e7\u00f5es integradas, inova\u00e7\u00e3o e confiabilidade. T\u00e9cnica. PU6AXE\",\"sameAs\":[\"https:\/\/machservicos.com.br\"],\"url\":\"https:\/\/machservicos.com.br\/?author=1\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE - MACH TECNOLOGIA","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/machservicos.com.br\/?p=680","og_locale":"pt_BR","og_type":"article","og_title":"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE - MACH TECNOLOGIA","og_description":"Entenda a norma t\u00e9cnica que define regras de montagem dos conectores para cabos de rede e suas especifica\u00e7\u00f5es.","og_url":"https:\/\/machservicos.com.br\/?p=680","og_site_name":"MACH TECNOLOGIA","article_published_time":"2026-01-29T00:22:12+00:00","article_modified_time":"2026-01-29T00:26:25+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia-1024x683.png","type":"image\/png"}],"author":"Tony Machado","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Tony Machado","Est. tempo de leitura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/machservicos.com.br\/?p=680#article","isPartOf":{"@id":"https:\/\/machservicos.com.br\/?p=680"},"author":{"name":"Tony Machado","@id":"https:\/\/machservicos.com.br\/#\/schema\/person\/6d4bcd2780673f815dfdd78bd1ad6a16"},"headline":"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE","datePublished":"2026-01-29T00:22:12+00:00","dateModified":"2026-01-29T00:26:25+00:00","mainEntityOfPage":{"@id":"https:\/\/machservicos.com.br\/?p=680"},"wordCount":811,"commentCount":0,"publisher":{"@id":"https:\/\/machservicos.com.br\/#organization"},"image":{"@id":"https:\/\/machservicos.com.br\/?p=680#primaryimage"},"thumbnailUrl":"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png","keywords":["cat6","conecto","eia","ethernet","norma","redes","RJ45","Tech","Technology","TIA"],"articleSection":["Automa\u00e7\u00e3o","Redes","Tecnologia"],"inLanguage":"pt-BR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/machservicos.com.br\/?p=680#respond"]}]},{"@type":"WebPage","@id":"https:\/\/machservicos.com.br\/?p=680","url":"https:\/\/machservicos.com.br\/?p=680","name":"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE - MACH TECNOLOGIA","isPartOf":{"@id":"https:\/\/machservicos.com.br\/#website"},"primaryImageOfPage":{"@id":"https:\/\/machservicos.com.br\/?p=680#primaryimage"},"image":{"@id":"https:\/\/machservicos.com.br\/?p=680#primaryimage"},"thumbnailUrl":"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png","datePublished":"2026-01-29T00:22:12+00:00","dateModified":"2026-01-29T00:26:25+00:00","breadcrumb":{"@id":"https:\/\/machservicos.com.br\/?p=680#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/machservicos.com.br\/?p=680"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/machservicos.com.br\/?p=680#primaryimage","url":"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png","contentUrl":"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png","width":1536,"height":1024},{"@type":"BreadcrumbList","@id":"https:\/\/machservicos.com.br\/?p=680#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/machservicos.com.br\/"},{"@type":"ListItem","position":2,"name":"Entenda a Norma TIA\/EIA-568: Sequ\u00eancia de Cores, Transmiss\u00e3o de Dados e PoE"}]},{"@type":"WebSite","@id":"https:\/\/machservicos.com.br\/#website","url":"https:\/\/machservicos.com.br\/","name":"MACH TECNOLOGIA","description":"Automa\u00e7\u00e3o residencial e seguran\u00e7a eletr\u00f4nica","publisher":{"@id":"https:\/\/machservicos.com.br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/machservicos.com.br\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/machservicos.com.br\/#organization","name":"MACH TECNOLOGIA","url":"https:\/\/machservicos.com.br\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/machservicos.com.br\/#\/schema\/logo\/image\/","url":"https:\/\/machservicos.com.br\/wp-content\/uploads\/2026\/01\/cropped-M-A-C-H-1.png","contentUrl":"https:\/\/machservicos.com.br\/wp-content\/uploads\/2026\/01\/cropped-M-A-C-H-1.png","width":380,"height":76,"caption":"MACH TECNOLOGIA"},"image":{"@id":"https:\/\/machservicos.com.br\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/machservicos.com.br\/#\/schema\/person\/6d4bcd2780673f815dfdd78bd1ad6a16","name":"Tony Machado","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/machservicos.com.br\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/47a6fc2f54315f40bb8c95e5a60db9c729e16a1061eb46d64604c7247cef394b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/47a6fc2f54315f40bb8c95e5a60db9c729e16a1061eb46d64604c7247cef394b?s=96&d=mm&r=g","caption":"Tony Machado"},"description":"Sou profissional de tecnologia com experi\u00eancia em seguran\u00e7a eletr\u00f4nica, automa\u00e7\u00e3o residencial e redes, focado em solu\u00e7\u00f5es integradas, inova\u00e7\u00e3o e confiabilidade. T\u00e9cnica. PU6AXE","sameAs":["https:\/\/machservicos.com.br"],"url":"https:\/\/machservicos.com.br\/?author=1"}]}},"jetpack_featured_media_url":"https:\/\/machservicos.com.br\/wp-content\/uploads\/2024\/02\/capamateriatia.png","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/machservicos.com.br\/index.php?rest_route=\/wp\/v2\/posts\/680","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/machservicos.com.br\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/machservicos.com.br\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/machservicos.com.br\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/machservicos.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=680"}],"version-history":[{"count":7,"href":"https:\/\/machservicos.com.br\/index.php?rest_route=\/wp\/v2\/posts\/680\/revisions"}],"predecessor-version":[{"id":845,"href":"https:\/\/machservicos.com.br\/index.php?rest_route=\/wp\/v2\/posts\/680\/revisions\/845"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/machservicos.com.br\/index.php?rest_route=\/wp\/v2\/media\/830"}],"wp:attachment":[{"href":"https:\/\/machservicos.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=680"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/machservicos.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=680"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/machservicos.com.br\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=680"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}